0% APR Financing* New Jersey Natural Gas customers may qualify for rebates & 0% APR financing on high-efficiency furnaces, boilers & water heaters through NJNG's SAVEGREEN program* Special Financing Available through Synchrony, subject to credit approval* Apply for Financing → *See details Call (732) 779-7106
24/7 Emergency · Call (732) 779-7106
Heating

Furnace Pilot Light Out or Won't Stay Lit? Causes, Safe Steps and When to Call

Why an older furnace pilot light goes out or will not stay lit (thermocouple, dirty pilot, drafts, gas supply), how to relight it safely, and when to call.

Illustration of a small blue gas pilot flame inside a furnace
LicensedNJ Master HVACR
In this guide

Quick answer: Only older furnaces have a standing pilot light; most furnaces made since the 1990s use electronic ignition instead. If your pilot is out or won't stay lit, the usual causes are a worn or misaligned thermocouple, a dirty pilot orifice, drafts, a kinked pilot tube, low gas pressure or a failing gas valve. Relight it only by following the instructions on the furnace label, and never if you smell gas. If it goes out again, book furnace repair. If you smell gas, leave the house and call 911 or your gas utility from outside.

Pilot light calls come mostly from older homes, where a 25- or 30-year-old furnace is still doing the job. That is common here: 63% of New Jersey homes were built before 1980 (U.S. Census Bureau, ACS 2020–2024), and gas heats 73% of homes statewide. Many of those homes have replaced their furnace since, but plenty of original or second-generation furnaces with standing pilots are still running in basements across Monmouth, Ocean and Burlington counties.

Does your furnace have a pilot light?

Look through the small window in the lower panel, or remove the front door if the label says it is safe to do so.

  • Standing pilot: a small blue flame burning all the time, even when the heat is off, next to the main burners. A knob on the gas valve reads Off, Pilot and On.
  • Electronic ignition: no flame while the furnace is idle. When the heat comes on, a small part glows orange (hot surface igniter) or you hear rapid ticking (spark igniter), then the burners light.

If you have electronic ignition, a "no heat" problem has different causes. See furnace won't ignite and furnace clicking but not turning on.

How a standing pilot works

The pilot flame heats a thermocouple, a small metal rod that produces a tiny electric current when hot. That current holds the gas valve open. If the pilot goes out, the thermocouple cools within a minute or two, the current stops, and the valve shuts the gas off. That is the safety system that stops unburned gas from filling the furnace.

So when a pilot "won't stay lit", the furnace is usually doing its job: something is stopping the thermocouple from proving there is a flame.

Why a pilot light goes out or won't stay lit

Symptom Likely cause
Lights, but goes out when you release the knob Worn or loose thermocouple
Weak, yellow or lazy flame Dirty pilot orifice or low gas pressure
Goes out on windy days Drafts or a downdraft in the chimney
Goes out when the burners light Low gas pressure, flame roll, venting problem
Will not light at all Gas off, air in the line, failing gas valve
Other gas appliances also out Gas supply problem; call the utility

Worn or misaligned thermocouple

The most common cause by far. Thermocouples wear out over years of heat, and a slightly bent one may sit outside the flame. The pilot lights while you hold the knob, then goes out as soon as you let go.

Dirty pilot orifice

Dust, rust and spider webs clog the tiny pilot opening. The flame becomes weak, yellow or floppy and does not heat the thermocouple properly. A healthy pilot flame is steady and mostly blue and wraps around the tip of the thermocouple.

Drafts

Open windows, a basement door, a nearby dryer vent or a downdraft in the chimney on windy days can blow a weak pilot out. Shore homes see more of this in winter storms.

Gas supply or valve problems

A partly closed gas cock, low supply pressure, air in the line after gas work, or a failing gas valve can all keep the pilot from staying lit. If your stove or water heater also lost gas, call your gas utility.

Venting and combustion problems

A blocked chimney or flue can starve the pilot of air or push combustion gases back toward it. This is a safety issue and needs a technician with a combustion analyzer. See carbon monoxide and furnace safety.

How to relight a pilot safely

Only do this if you do not smell gas. Follow the lighting instructions printed inside your furnace door; they come first. The usual steps are:

  1. Turn the thermostat down and switch off power to the furnace.
  2. Turn the gas valve knob to Off and wait at least five minutes for any gas to clear.
  3. Turn the knob to Pilot.
  4. Press and hold the knob (or the separate reset button) and light the pilot with a long lighter or the built-in igniter button.
  5. Keep holding for about 60 seconds so the thermocouple heats up.
  6. Release slowly. If the pilot stays lit, turn the knob to On, restore power and raise the thermostat.

If the pilot goes out again when you release the knob, stop. Repeated attempts will not fix a worn thermocouple, and you should not keep releasing gas. Book a repair.

Signs you should not relight it yourself

  • Any smell of gas (leave and call from outside)
  • Scorch marks, soot or melted wires near the burners
  • The flame is yellow, orange or lifting off the burner (see furnace flame color)
  • A carbon monoxide alarm has sounded (see CO detector beeping)
  • You are not comfortable working with gas

How we fix it

We confirm the gas supply and pressure, clean the pilot orifice and assembly, test the thermocouple's output, replace and position it correctly if needed, check the gas valve, inspect the flue and chimney for draft, and test for carbon monoxide before we leave. Most pilot problems are a straightforward, single-visit repair. You get an upfront price before any work. See what affects furnace repair cost.

Is it time to replace a standing-pilot furnace?

A furnace with a standing pilot is usually from the early 1990s or before, so it is often 30 years old or more. Most gas furnaces last about 15 to 20 years. Older furnaces also tend to have efficiencies around 60 to 80% AFUE, compared with 95% or more for a new high-efficiency furnace, and the pilot itself burns gas around the clock.

A repair still makes sense in an emergency or if the furnace is in good condition. But if your furnace is this old and needs a gas valve, has a rusting heat exchanger, or has needed several repairs, it is worth comparing replacement. See signs you need a new furnace, is a high-efficiency furnace worth it and what a new system costs.

New systems qualify for $500 off (terms apply). You can pay over time with financing through Synchrony, subject to credit approval, and New Jersey Natural Gas customers may qualify for rebates and 0% APR financing on qualifying high-efficiency furnaces through NJNG's SAVEGREEN program (provided by NJNG, not Prime Comfort Group; terms and eligibility apply).

Water heaters have pilots too

Many tank water heaters in New Jersey basements use a standing pilot as well, and the causes are similar. See water heater pilot won't stay lit.

Preventing pilot problems

  • Book a yearly tune-up that cleans the pilot assembly and checks the thermocouple
  • Keep the area around the furnace clean and free of dust and stored items
  • Fix drafts near the furnace and keep the burner door in place
  • Have the chimney or flue checked, especially after storms

Our heating tune-up is $89 (terms apply), and the Prime Comfort Club covers one heating and one AC tune-up a year for $19/month (terms apply).

Furnace repair near you

Our own licensed team repairs older and newer furnaces of every brand across all 153 towns in Ocean, Monmouth, Burlington and Middlesex counties, including Toms River, Neptune, Long Branch and Willingboro. Work is performed under NJ Master HVACR License 19HC00844400.

Pilot out and the house getting cold? Book online or call (732) 779-7106, 24/7. New customers save $50 on their first repair (terms apply).

Need a licensed HVAC pro today? Same day service across Ocean, Monmouth, Burlington & Middlesex counties. Upfront pricing, 24/7 emergency help.
Book online Call (732) 779-7106

Frequently asked questions

Why does my furnace pilot light keep going out?

The most common causes are a worn or misaligned thermocouple, a dirty pilot orifice that makes a weak flame, drafts near the furnace, a kinked pilot tube, low gas pressure or a failing gas valve.

How do I relight my furnace pilot light?

Follow the lighting instructions printed on the label inside the furnace door: turn the gas knob to Off and wait at least five minutes, then to Pilot, hold it down while you light the pilot, keep holding for about a minute, then release and turn it to On. Never relight if you smell gas.

Is it dangerous if the pilot light goes out?

The thermocouple is designed to shut off gas when the pilot goes out, so a pilot that is simply out is usually not dangerous. If you smell gas, leave the house and call 911 or your gas utility from outside.

How much does it cost to replace a furnace thermocouple?

A thermocouple is a small, inexpensive part, and replacement is a routine repair. The total depends on access and what else the technician finds. We give an upfront price before any work.

Does my furnace have a pilot light?

If your furnace is from the early 1990s or older and you can see a small blue flame burning all the time, it has a standing pilot. Most newer furnaces use a hot surface or spark igniter instead.

Furnace & Heating Repair near you

We provide furnace & heating repair in all 153 towns across Ocean, Monmouth, Burlington and Middlesex counties. Find your area:

Ocean County (all 35 towns)

Monmouth County (all 53 towns)

Burlington County (all 40 towns)

Middlesex County (all 25 towns)

About Prime Comfort Group

A family-owned heating, cooling and hot water company based in Toms River, NJ. Our work is led by Cornelius VanTeeling, a licensed NJ Master HVACR contractor with 40 years of experience, together with founder Neal Prasad.

NPNeal PrasadFounder · U.S. Marine Corps VeteranCVCornelius VanTeelingLicensed NJ Master HVACR Professional · Partner
Meet the team

Local HVAC help nearby

Same day service

Too hot? Too cold? Let’s fix that today.

Book online in about a minute or call us for honest advice and an upfront quote. Same day service across Ocean, Monmouth, Burlington and Middlesex counties.

  • $50 off your first repair (new customers, terms apply)
  • 24/7 emergency line
  • Upfront quotes
  • No hidden fees
  • Licensed & family owned
Call