In this guide
Quick answer: Most furnaces restart on their own when power comes back. If yours doesn't, check the breaker, the furnace service switch (it looks like a light switch near the furnace), and the thermostat, which may have reset or lost its schedule. Then turn the furnace power off for 30 seconds and back on once. If it still won't run, or a light is blinking an error code, the outage may have caused a safety lockout or surge damage to the control board, igniter or blower. Book furnace repair. If you smell gas, leave the house and call 911 or your gas utility from outside.
Winter storms and nor'easters regularly knock out power along the Jersey Shore and inland. When the lights come back, most heating systems pick up where they left off. When one doesn't, the cause is usually simple, but sometimes the outage itself did the damage. Here is how to tell the difference safely, what you can check yourself, and when it's time to call.
Why the outage can stop the furnace
A modern gas furnace is an electrical appliance that burns gas. It needs power for the thermostat, the control board, the inducer fan, the igniter, the gas valve and the blower. Oil furnaces and boilers need power for the burner motor and controls too. During an outage, and especially when power flickers on and off, several things can happen:
- The breaker trips when the power returns with a surge.
- The furnace tries to start several times during flickering power and goes into a safety lockout.
- The thermostat resets to factory settings, or its batteries are low and it never calls for heat.
- A power surge damages electronics: the control board, a hot surface igniter, an inducer motor, or a variable-speed blower motor. Ready.gov warns that power may return with momentary surges or spikes that can damage equipment.
- On high-efficiency furnaces, a condensate pump that lost power may have filled up and tripped a safety switch.
Normal start-up: what you should see and hear
Knowing the normal sequence helps you see where it stops. When the thermostat calls for heat, a gas furnace usually:
- Starts the inducer fan (a small motor hum) to clear the vent.
- Proves the vent is clear through the pressure switch (a soft click).
- Heats the igniter (an orange glow) or sparks a pilot.
- Opens the gas valve, and the burners light.
- After 30 to 60 seconds, starts the main blower, and warm air comes from the vents.
If nothing at all happens, the problem is power or the thermostat. If the inducer runs but there's no glow, look at the igniter or pressure switch. If the burners light and then shut off, the flame sensor or a limit switch is the usual suspect. That's useful information to give us when you call, and it often lets us bring the right part on the first visit.
Step-by-step checks
- Smell for gas first. If you smell gas, don't touch switches. Leave and call 911 or your gas utility from outside. See what to do if you smell gas near the furnace.
- Thermostat: set it to Heat, a few degrees above room temperature. Replace the batteries if the screen is blank or dim. Smart thermostats may need a minute to reconnect to Wi-Fi.
- Breaker: find the furnace or air handler breaker in your panel. If it's in the middle position, switch it fully off, then on.
- Furnace switch: make sure the service switch near the furnace is on, and the front panel is closed tight (an open panel cuts power through a safety switch).
- Look for a blinking light through the furnace window and count the flashes. See furnace blinking light codes.
- Reset once: power off for about 30 seconds, then on. See how to reset your furnace safely.
- Condensate pump: on high-efficiency furnaces, check the small pump near the furnace isn't full of water.
- Outside vents: if the outage came with a snowstorm, check that the white plastic intake and exhaust pipes outside aren't buried.
If the furnace still doesn't start, stop resetting it. Repeated resets can hide the real fault.
What a surge can damage
| Part | What you might notice | Typical next step |
|---|---|---|
| Control board | No lights, or erratic behavior | Diagnose and replace if failed |
| Hot surface igniter | Inducer runs, no glow, no flame | Test and replace |
| Inducer motor | No hum before ignition | Test motor and capacitor |
| Blower motor (ECM) | Burners light, then shut off on high limit | Test the motor module |
| Thermostat | Blank screen, no call for heat | Check wiring, replace if failed |
| Condensate pump | Water near furnace, no start | Clear or replace pump |
A blown low-voltage fuse on the control board is another common result of a surge or a shorted thermostat wire. It's a cheap part, but the cause needs to be found before it's replaced, or the new fuse blows too.
Heat pumps after an outage
Heat pumps and air conditioners usually wait a few minutes before restarting to protect the compressor. After a long outage in very cold weather, some manufacturers recommend leaving power on for several hours before running the compressor, so the crankcase heater can warm the oil. In the meantime, the thermostat's Emergency Heat setting can run the backup heat. See emergency heat vs aux heat. If the outdoor unit is covered in ice after a storm, see heat pump iced up in winter.
Boilers after an outage
Hot water boilers need power for the burner controls and circulator pumps. If the boiler fires but radiators stay cold, the circulator may not have restarted or may be air-bound. Check the pressure gauge, then call. See boiler not heating.
Common mistakes after an outage
- Resetting over and over. One reset is a test; five resets is a guess that can make diagnosis harder.
- Leaving the thermostat calling for heat during flickering power. Every flicker is another start attempt and another surge.
- Heating with the oven or a grill. The CDC says to never heat your house with a gas oven, and grills and unvented heaters are just as dangerous indoors.
- Removing the furnace door to "see better" and leaving it off. The door switch stops the furnace, and an open door can draw exhaust into the room.
- Ignoring a CO alarm because "it's just the outage." Treat every alarm as real.
While you wait for repair
Keep the house as warm as you safely can: close doors to unused rooms, open curtains on sunny windows, and drip faucets on outside walls if temperatures drop below freezing. Ready.gov suggests going to a community location with power if the cold is extreme. See no heat and frozen pipes and space heater safety.
Why this matters at the shore and inland
Storm outages hit both the barrier islands and the inland Pine Barrens towns, where homes are more spread out and repairs can take longer. Gas heats 73% of New Jersey homes, and 63% were built before 1980 (U.S. Census Bureau, ACS 2020–2024), so many systems have older controls, and many newer furnaces have electronics that are expensive to replace. Planning for outages protects both.
Protect your system from the next outage
- Surge protection: a whole-home surge protector at the panel, or a dedicated HVAC surge device, helps protect boards and motors.
- Turn the thermostat off during a long outage, then back on a few minutes after power returns, so the system doesn't restart into flickering power. Ready.gov also advises disconnecting appliances and electronics to avoid surge damage.
- Generator planning: if you rely on a generator, make sure it is sized and connected correctly. See can a generator run a furnace.
- CO alarms with battery backup near every sleeping area, as the CDC recommends, because many plug-in alarms stop working when the power is out.
- Yearly tune-up: a technician checks the igniter, board and motors for early signs of failure. See what's included in a furnace tune-up.
Our heating tune-up is $89 (terms apply), and the Prime Comfort Club covers one heating and one AC tune-up a year for $19/month (terms apply).
How we fix it
We confirm power at the furnace and thermostat, read stored fault codes, test the control board, igniter, inducer, blower and safety switches, check the condensate system, and test for carbon monoxide before we leave. You get an upfront price before any repair. If a surge-damaged part is expensive on an older furnace, we explain repair versus replacement honestly. See furnace repair cost factors and repair or replace your furnace.
Furnace repair near you
Our own licensed team handles post-storm heating calls 24/7 across all 153 towns in Ocean, Monmouth, Burlington and Middlesex counties, including Toms River, Brick, Jackson and Howell. Work is performed under NJ Master HVACR License 19HC00844400.
Power's back but the heat isn't? Book online or call (732) 779-7106, 24/7. New customers save $50 on their first repair (terms apply).
Frequently asked questions
Why is my furnace not working after a power outage?
The most common causes are a tripped breaker, the furnace service switch turned off, a thermostat that reset or lost its schedule, a safety lockout from repeated restart attempts, or a component damaged by a power surge such as the control board, igniter or blower motor.
How do I reset my furnace after a power outage?
Check the breaker and the furnace service switch, confirm the thermostat is set to Heat above room temperature, then turn the furnace power off for about 30 seconds and back on once. If it still does not start, call for service rather than resetting repeatedly.
Can a power surge damage a furnace?
Yes. Power can return with momentary surges or spikes, and those can damage electronic control boards, igniters, inducer motors and variable-speed blower motors. A whole-home or HVAC surge protector reduces the risk.
How long should I wait for the furnace to start after power comes back?
A gas furnace normally starts its sequence within a minute or two of the thermostat calling for heat: inducer, igniter, burners, then the blower. If nothing happens after about five minutes with the thermostat set correctly, start the checks in this guide.
Why does my heat pump wait before starting after the power comes back?
Many heat pumps and air conditioners have a built-in delay of a few minutes to protect the compressor, and some manufacturers recommend several hours of power to the crankcase heater after a long outage in cold weather. Check your manual before forcing a restart.
My thermostat screen is blank after the outage. What should I do?
Replace the batteries if it uses them, then check the furnace breaker and service switch, because many thermostats are powered by the furnace. If the screen stays blank with power at the furnace, the thermostat, its wiring or a fuse on the control board may need service.
Is it safe to keep resetting the furnace?
No. One reset is fine. Repeated resets can hide a real fault, flood the heat exchanger area with unburned gas on some models, or keep the furnace in lockout. If one reset does not fix it, book a repair.
Do you offer emergency furnace repair after storms?
Yes. We offer same day furnace repair and a 24/7 emergency line across Ocean, Monmouth, Burlington and Middlesex counties, with an upfront price before any work.
Furnace & Heating Repair near you
We provide furnace & heating repair in all 153 towns across Ocean, Monmouth, Burlington and Middlesex counties. Find your area:
Monmouth County (all 53 towns)
Too hot? Too cold? Let’s fix that today.
Book online in about a minute or call us for honest advice and an upfront quote. Same day service across Ocean, Monmouth, Burlington and Middlesex counties.
- $50 off your first repair (new customers, terms apply)
- 24/7 emergency line
- Upfront quotes
- No hidden fees
- Licensed & family owned
Install our app
On your iPhone or iPad, in Safari:
- Tap the Share button ↑︎ at the bottom of the screen
- Scroll down and tap Add to Home Screen
- Tap Add. The app appears on your home screen
Using Chrome on iPhone? Tap the share icon in the address bar, then Add to Home Screen.
On your Android phone, in Chrome:
- Tap the menu ⋮ at the top right
- Tap Install app (or Add to Home screen)
- Tap Install. The app appears on your home screen
No app store, no sign-up needed. Book service, track appointments and see your invoices and receipts.